High Granularity Readout Time Projection Chamber Technology for e+e- Collider Physics

Not scheduled
20m

Speaker

Huirong Qi (Insititute of High Energy Physics, CAS)

Description

The Circular Electron Positron Colliders (FCCee and CEPC) were proposed as the Higgs and Z operation in High Energy Physics communities. In the tracker detector concept, as well as in comparable detector designs, the baseline detector design features a high-precision (approximately 100 μm) spatial resolution Time Projection Chamber (TPC) as the main tracking device surround a 3.0T solenoid field. The TPC is required to provide a standalone momentum resolution of 10⁻⁴ (GeV/c)⁻¹, and the physics requirement of Particle Indentification (PID) resolution should be reached less than 3%. TPC performance is satisfactory in Higgs mode, but high luminosity Z pole running poses substantial technical challenges requiring rigorous evaluation of feasibility and mitigation strategies.
Based on the latest MDI background simulation data, we have assessed ion-induced space charge effects in the TPC under Z-pole running conditions. The updated estimation at FCC-ee Week 2026 revealed that synchrotron radiation background at Tera-Z is ~3 orders of magnitude higher than incoherent pair creation, posing extreme challenges for all detectors. Our full simulation chain shows maximum space charge densities of 1.7 nC/m³ (Higgs) and 3.3 nC/m³ (low-lumi Z), causing ~50% momentum resolution degradation at high pT for TPC-only tracking, improved to ~20% with silicon trackers. Crucially, MDI optimization—aluminum beampipe and tungsten shielding—reduces photon flux by ~85%, suppressing space charge below 0.8 nC/m³ and controlling resolution degradation under 10%, confirming TPC feasibility through collaborative MDI optimization. In this talk, the feasibility and update progress of high precision TPC as the main track detector for e+ e− collider will be presented. TPC detection aims the good separation power with the cluster counting to be considered and the simulation results of the pad/pixelated TPC technology for e+ e− collider will be given. Compared with the pad readout using the simulation, the high granularity readout TPC option (500μm × 500μm) will obtain the better spatial resolution of single electrons, the very high detection efficiency in excellent tracking and good PID performance (less than 3σ).

Authors

Huirong Qi (Insititute of High Energy Physics, CAS) Dr Jianbo Zheng (Institute of High Energy Physics, CAS) Dr Jinxian Zhang (Institute of High Energy Physics, CAS)

Presentation materials

There are no materials yet.